FIND YOUR REMOTE

Find your remote and compatable JMA Remote to copy

Legend: Click on the symbols for further information

Frequency

Type of code

  1. Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
  2. Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.

Buttons

Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.

PROCESS:

  1. In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
  2. Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.

If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.

Copy

No copy

FOR: DITEC® BIX

  • F 40,685
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-Q MAX
DITEC® BIX

See compatible JMA remotes

FOR: DITEC® BIXAG

  • F 40,685
  • C FIX CODE
  • B 4
  • AP NO
  • M-Q MAX
DITEC® BIXAG

See compatible JMA remotes

FOR: DITEC® BIXLG

  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP NO
  • BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DITEC® BIXLG

See compatible JMA remotes

Synchronising intructions

Print

SYNCHRONISING DITEC ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the DITEC remote control

1. Stand near the receiver and use a pointed object to press the button located below the central orifice of the Ditec remote control already synchronised in the facility for 5 seconds.

The LED on the master remote control will begin to flash after 5 seconds, indicating that it is ordering the receiver to enter synchronisation mode.

2. Press the synch button of the duplicated device.

The code of the new device is sent to the receiver and stored.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Direct synchronisation procedure for the DITEC remote control

1. Open the receiver and press the small button marked PROG for 2 seconds.

The receiver LED will light up.

2. Press the synch button of the duplicated device.

The receiver LED will flash once and return to steady.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

FOR: DITEC® BIXLP

  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP NO
  • BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DITEC® BIXLP

See compatible JMA remotes

Synchronising intructions

Print

SYNCHRONISING DITEC ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the DITEC remote control

1. Stand near the receiver and use a pointed object to press the button located below the central orifice of the Ditec remote control already synchronised in the facility for 5 seconds.

The LED on the master remote control will begin to flash after 5 seconds, indicating that it is ordering the receiver to enter synchronisation mode.

2. Press the synch button of the duplicated device.

The code of the new device is sent to the receiver and stored.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Direct synchronisation procedure for the DITEC remote control

1. Open the receiver and press the small button marked PROG for 2 seconds.

The receiver LED will light up.

2. Press the synch button of the duplicated device.

The receiver LED will flash once and return to steady.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

FOR: DITEC® BIXLS

  • F 433,92
  • C FIX CODE
  • B 2
  • AP NO
  • BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DITEC® BIXLS

See compatible JMA remotes

FOR: DITEC® GOL4

  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP NO
  • BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DITEC® GOL4

See compatible JMA remotes

Synchronising intructions

Print

SYNCHRONISING DITEC ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the DITEC remote control

1. Stand near the receiver and use a pointed object to press the button located below the central orifice of the Ditec remote control already synchronised in the facility for 5 seconds.

The LED on the master remote control will begin to flash after 5 seconds, indicating that it is ordering the receiver to enter synchronisation mode.

2. Press the synch button of the duplicated device.

The code of the new device is sent to the receiver and stored.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Direct synchronisation procedure for the DITEC remote control

1. Open the receiver and press the small button marked PROG for 2 seconds.

The receiver LED will light up.

2. Press the synch button of the duplicated device.

The receiver LED will flash once and return to steady.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

FOR: DITEC® GOL4C

  • F 433,92
  • C FIX CODE
  • B 4
  • AP NO
  • BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DITEC® GOL4C

See compatible JMA remotes