Legend: Click on the symbols for further information

Frequency

Type of code

  1. Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
  2. Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.

Buttons

Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.

PROCESS:

  1. In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
  2. Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.

If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.

Copy

No copy

HORMANN® HSBS Remote

Remove Remote
  • F 868,3
  • C ROLLING CODE
  • B 2,4
  • AP NO
  • M-BT Advance
HORMANN® HSBS

DITEC® GOL4 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DITEC® GOL4

Synchronising intructions

Print

SYNCHRONISING DITEC ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the DITEC remote control

1. Stand near the receiver and use a pointed object to press the button located below the central orifice of the Ditec remote control already synchronised in the facility for 5 seconds.

The LED on the master remote control will begin to flash after 5 seconds, indicating that it is ordering the receiver to enter synchronisation mode.

2. Press the synch button of the duplicated device.

The code of the new device is sent to the receiver and stored.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Direct synchronisation procedure for the DITEC remote control

1. Open the receiver and press the small button marked PROG for 2 seconds.

The receiver LED will light up.

2. Press the synch button of the duplicated device.

The receiver LED will flash once and return to steady.

3. Wait for 10 seconds for the receiver to exit synchronisation mode.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

ECOSTAR® RSC Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
ECOSTAR® RSC

Synchronising intructions

Print

SYNCHRONISING ECOSTAR ROLLING CODE REMOTE CONTROLS

ECOSTAR remote controls can only be synchronised directly on the receiver.

Direct synchronisation procedure on the receiver

1. Press the button marked P on the PLC or receiver casing. The red LED will begin to flash, indicating that the receiver is in synchronisation mode.

2. Press and hold the button on the remote control until the LED changes to quick flash. Release the button.

3. Press the button on the remote control again and hold until the LED emits very quick flashes. Release the button.

4. The end of the very quick flash phase indicates that the remote control code has been stored.

HORMANN® HS 40 Remote

Remove Remote
  • F 40,685
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-Q MAX 2 / M-Q MAX 1
HORMANN® HS 40

SPACE® SP Remote

Remove Remote
  • F 433,92MHz
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-NOVA PRO / BT Slim / M-BT Biometric / M-BT Advance
SPACE® SP

NORTON® TX 868 Remote

Remove Remote
  • F 868,3
  • C ROLLING CODE
  • B 2
  • AP NO
NORTON® TX 868

ROPER® MINI GO Remote

Remove Remote
  • F 868,3
  • C ROLLING CODE
  • B 2
  • AP YES
  • M-BT Biometric / BT Slim / M-BT Advance / SR-48
ROPER® MINI GO

Synchronising intructions

Print

SYNCHRONISING GO ROLLING CODE REMOTE CONTROLS

The GO remote control is synchronised directly with the receiver the first time the button is pressed. However, this option is disabled on some models, which must be synchronised manually.

GO remote control manual synchronisation procedure

1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".

2. Press the button or turn on the switch.

3. Within ten (10) seconds of the beep, press the button on the device to be synchronised.

The receiver will emit another short beep to indicate that the remote control has been synchronised.

If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.

4. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

CAME® T152 Remote

Remove Remote
  • F 30,9
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-Q MAX 1
CAME® T152

ELVOX® ETR 2 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
ELVOX® ETR 2

Synchronising intructions

Print

HOW TO SYNCHRONISE ELVOX ROLLING CODE REMOTE CONTROLS

ELVOX remote control synchronisation can only be performed directly on the receiver itself.

Synchronising the remote control directly on the receiver

Sliding and hinged doors

1. Hold the button on the receiver I2(P2).

2. While still holding the button on the receiver, press the button on the remote control to be synchronised.

3. Wait for the LED to flash, confirming the synchronisation.

4. Release both buttons.

ECRU receiver

1. Hold the button on the P1 receiver for two seconds. The DL1 LED will flash green.

2. Release the P1 button on the receiver.

3. Press button 1 on the remote control to be programmed.

4. The blue DL5 LED will flash.

5. On pressing the P1 button again for two seconds, the DL2 LED will flash green to synchronise channel 2.

6. Press button 2 on the remote control to be programmed.

7. The blue DL5 LED will flash.

8. To synchronise buttons 3 and 4, repeat steps 5 to 7. The LEDs DL3 and DL4 will light. Press buttons 3 and 4 in each case.

9. To leave synchronisation mode, press buttons P1 and P2 when the green LED flashes while waiting for a signal.

CHAMBERLAIN 2.0® 951EV Remote

Remove Remote
  • F 310,315,390 MHz
  • C ROLLING CODE
  • B 1
  • AP NO
  • M-BT Biometric / BT Slim / M-BT Advance
CHAMBERLAIN 2.0® 951EV

Synchronising intructions

Print

SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS

The Lift Master remote control can only be synchronised directly on the receiver.

Direct synchronisation procedure on the receiver

1. Press the button on the remote control and hold.

2. Press and release the Learn button for channel A on the receiver.

3. The control LED will flash once.

4. Release the remote control button.

If you release the remote control button before the control LED flashes the receiver will not accept the code.

Repeat this procedure for any other devices you wish to add.

If you are using a second door, select another button on the remote control and repeat the steps for channel B.

ET SYSTEM® MIX Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2,4
  • AP NO
  • M-BT Biometric / BT Slim / M-NOVA PRO / M-BT Advance
ET SYSTEM® MIX

Synchronising intructions

Print

HOW TO SYNCHRONISE ET BLUE AND ET BLUE MIX ROLLING CODE REMOTE CONTROLS

ET BLUE and ET BLUE MIX remote control synchronisation can only be performed directly on the receiver itself.

Synchronising the remote control directly on the receiver

1. Press SET until “Pr9” appears on the display.

2. Browse the menu with the UP and DOWN buttons until “Lrn” appears on the display.

3. Press SET until “ch1” appears on the display.

4. Press the button on the remote control to be synchronised.

5. After being programmed, “dnE” will appear on the display.

6. To record more channels, press UP and DOWN until “ch2” or “ch3” appears on the display and press the button on the remote control to be synchronised.

7. To finish, press SET until “End” appears on the display.

GENIUS® BRAVO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
GENIUS® BRAVO

Synchronising intructions

Print

SYNCHRONISING GENIUS ROLLING CODE REMOTE CONTROLS

GENIUS remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.

Remote synchronising procedure

1. Press and hold buttons P1 and P2 on the remote control already synchronised in the facility for at least 5 seconds.

2. Within 10 seconds, press the same button on the remote control already synchronised in the facility as the one you wish to synchronise.

3. The receiver will enter synchronisation mode and the LED for the active channel will light up steady.

4. Press the button you wish to synchronise on the new remote control.

5. Repeat Step 4 if you wish to add more remote controls.

6. Wait for 10 seconds for the receiver to exit synchronisation mode.

7. Repeat the process for the other channel.

Direct synchronisation procedure on the receiver1. Press the button on the receiver for the channel you wish to synchronise - SW1 to synchronise CH1 and SW2 to synchronise CH2. Either LED 1 or LED 2 will light up steady indicating that the receiver is in synchronisation mode.

2. Within 10 seconds press and hold the button you wish to synchronise on the remote control for at least 1 second.

3. If synchronisation is successful, the LED will flash a couple of times.

4. Repeat the process from Step 2 to synchronise additional remote controls.

5. The receiver will automatically exit synchronisation mode 10 seconds after the last synchronisation.

CRAWFORD® T-433 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
CRAWFORD® T-433

Synchronising intructions

Print

SYNCHRONISING CRAWFORD/NORMSTHAL ROLLING CODE REMOTE CONTROLS

CRAWFORD/NORMSTHAL remote controls can only be synchronised directly on the receiver by taking the following steps.

Synchronisation procedure using the receiver

1. Press the SET button:

Once for impulse response (the receiver is active while the button is being held)

Twice for flip-flop response (the receiver is active until the next time it is pressed)

Three times for ON

Four times for OFF

2. Press the button of the device to be synchronised

3. The LED will flash, indicating that the code has been stored.

TELCOMA® FOX 30 Remote

Remove Remote
  • F 30,875
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-Q MAX 1
TELCOMA® FOX 30

DITEC® ZEN4 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP NO
  • M-NOVA PRO / BT Slim / M-BT Biometric / M-BT Advance / SR-4V / SR-48
DITEC® ZEN4

STAGNOLI® ZEUS Remote

Remove Remote
  • F 433,92
  • C FIX CODE
  • B 3
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
STAGNOLI® ZEUS

FADINI® JUBI SMALL Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
FADINI® JUBI SMALL

Synchronising intructions

Print

SYNCHRONISING FADINI ROLLING CODE REMOTE CONTROLS

FADINI remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.

Remote synchronisation procedure

1. Press buttons 1 and 2 simultaneously on the new remote control and hold for 10 seconds.

2. Release, and before 15 seconds elapse press buttons 1 and 2 of the device already synchronised in the facility and hold for at least 10 seconds.

3. Finally, press any button of the device to be synchronised.

Direct synchronisation procedure on the receiver

1. In the receiver, use a jumper to bypass C1.

2. Press button P in the receiver and button 1 on the remote control to be synchronised for 5 seconds.

3. Release the buttons on both devices and remove the jumper.

4. Repeat the operation for all channels, bypassing the relevant channel each time (C2, C3 and C4).

NORTON® NEO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 1,2,3,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
NORTON® NEO

Synchronising intructions

Print

SYNCHRONISING JCM ROLLING CODE REMOTE CONTROLS

The JCM rolling code remote control synchronisation procedure is identical for all models except the 868 MHz.

There are 3 synchronisation procedures for these devices.

PIN-MODE remote synchronising procedure

The following procedure must be applied if the receiver bears the words PIN-MODE:

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the remote control to be synchronised.

The receiver will emit a long beep, indicating that the device has been successfully synchronised.

Remote synchronisation procedure using the original remote control

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the synchronised remote control.

The receiver will emit a beep, indicating that it has switched to synchronisation mode.

2. Within 10 seconds of the beep, press the button on the device to be synchronised.

The receiver will emit another short beep to indicate that the remote control has been synchronised.

If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.

3. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".

2. Press the button or turn on the switch.

The receiver will emit a long beep and the LED will light up. From this point, follow the previous procedure from step 2 above.

PUJOL® NEO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 1,2,3,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
PUJOL® NEO

Synchronising intructions

Print

SYNCHRONISING JCM ROLLING CODE REMOTE CONTROLS

The JCM rolling code remote control synchronisation procedure is identical for all models except the 868 MHz.

There are 3 synchronisation procedures for these devices.

PIN-MODE remote synchronising procedure

The following procedure must be applied if the receiver bears the words PIN-MODE:

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the remote control to be synchronised.

The receiver will emit a long beep, indicating that the device has been successfully synchronised.

Remote synchronisation procedure using the original remote control

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the synchronised remote control.

The receiver will emit a beep, indicating that it has switched to synchronisation mode.

2. Within 10 seconds of the beep, press the button on the device to be synchronised.

The receiver will emit another short beep to indicate that the remote control has been synchronised.

If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.

3. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".

2. Press the button or turn on the switch.

The receiver will emit a long beep and the LED will light up. From this point, follow the previous procedure from step 2 above.

WAYNE DALTON® 5BWSB433 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 5
  • AP NO
WAYNE DALTON® 5BWSB433

ROPER® GO Remote

Remove Remote
  • F 868,3
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-BT Advance / SR-48
ROPER® GO

Synchronising intructions

Print

SYNCHRONISING GO ROLLING CODE REMOTE CONTROLS

The GO remote control is synchronised directly with the receiver the first time the button is pressed. However, this option is disabled on some models, which must be synchronised manually.

GO remote control manual synchronisation procedure

1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".

2. Press the button or turn on the switch.

3. Within ten (10) seconds of the beep, press the button on the device to be synchronised.

The receiver will emit another short beep to indicate that the remote control has been synchronised.

If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.

4. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

ROPER® NEO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 1,2,3,4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
ROPER® NEO

Synchronising intructions

Print

SYNCHRONISING JCM ROLLING CODE REMOTE CONTROLS

The JCM rolling code remote control synchronisation procedure is identical for all models except the 868 MHz.

There are 3 synchronisation procedures for these devices.

PIN-MODE remote synchronising procedure

The following procedure must be applied if the receiver bears the words PIN-MODE:

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the remote control to be synchronised.

The receiver will emit a long beep, indicating that the device has been successfully synchronised.

Remote synchronisation procedure using the original remote control

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the synchronised remote control.

The receiver will emit a beep, indicating that it has switched to synchronisation mode.

2. Within 10 seconds of the beep, press the button on the device to be synchronised.

The receiver will emit another short beep to indicate that the remote control has been synchronised.

If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.

3. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".

2. Press the button or turn on the switch.

The receiver will emit a long beep and the LED will light up. From this point, follow the previous procedure from step 2 above.

EMFA® NEO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 1,2,3,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
EMFA® NEO

Synchronising intructions

Print

SYNCHRONISING JCM ROLLING CODE REMOTE CONTROLS

The JCM rolling code remote control synchronisation procedure is identical for all models except the 868 MHz.

There are 3 synchronisation procedures for these devices.

PIN-MODE remote synchronising procedure

The following procedure must be applied if the receiver bears the words PIN-MODE:

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the remote control to be synchronised.

The receiver will emit a long beep, indicating that the device has been successfully synchronised.

Remote synchronisation procedure using the original remote control

1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the synchronised remote control.

The receiver will emit a beep, indicating that it has switched to synchronisation mode.

2. Within 10 seconds of the beep, press the button on the device to be synchronised.

The receiver will emit another short beep to indicate that the remote control has been synchronised.

If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.

3. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".

2. Press the button or turn on the switch.

The receiver will emit a long beep and the LED will light up. From this point, follow the previous procedure from step 2 above.

ELEMAT® K30 Remote

Remove Remote
  • F 30,9
  • C FIX CODE
  • B 1,2,4
  • AP NO
  • M-Q MAX 1
ELEMAT® K30

TELCOMA® FM402 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
TELCOMA® FM402

Synchronising intructions

Print

SYNCHRONISING TELCOMA FM ROLLING CODE REMOTE CONTROLS

TELCOMA FM remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.

Remote synchronisation procedure

This procedure requires at least one four-channel remote control with the previous system already synchronised with the receiver.

1. Press the 4 buttons on the remote control already synchronised with the receiver simultaneously for 3 seconds.

2. Release, and within 2 seconds briefly press, on the same original device, the button that the receiver has already synchronised.

3. Within 2 seconds press the button of the remote control you wish to synchronise.

4. Repeat the process for the remaining buttons if necessary.

Direct synchronisation procedure on the receiver

1. On the receiver, press the P button associated with the channel to be synchronised with the remote control.

2. The LED will flash 5 times.

3. While the LED is flashing press the button on the remote control associated with the code to be synchronised.

4. If synchronisation is successful, the LED will emit a long flash.

5. Repeat the operation for all other remote controls you wish to synchronise.

ECOSTAR® RSE Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
ECOSTAR® RSE

Synchronising intructions

Print

SYNCHRONISING ECOSTAR ROLLING CODE REMOTE CONTROLS

ECOSTAR remote controls can only be synchronised directly on the receiver.

Direct synchronisation procedure on the receiver

1. Press the button marked P on the PLC or receiver casing. The red LED will begin to flash, indicating that the receiver is in synchronisation mode.

2. Press and hold the button on the remote control until the LED changes to quick flash. Release the button.

3. Press the button on the remote control again and hold until the LED emits very quick flashes. Release the button.

4. The end of the very quick flash phase indicates that the remote control code has been stored.

CENTURION® NOVA-TX Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 1 ,2,4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
CENTURION® NOVA-TX

Synchronising intructions

Print

HOW TO SYNCHRONISE CENTURION ROLLING CODE REMOTE CONTROLS

CENTURION remote control synchronisation can only be performed directly or via radio if you own a MASTER remote control or a VOYAGE receiver.

NOVA and SMART Receiver

Synchronising the remote control directly on the receiver

1. Switch the jumper to the LEARN position.

2. The LED will light up red.

3. Press the button on the remote control to be recorded. The LED will flash.

4. Remove the jumper and leave it disconnected.

NOVA VOYAGE Receiver

Synchronising the remote control directly on the receiver

1. Switch the jumper to the LEARN position.

2. The LED will light up red.

3. Press the button on the remote control to be recorded. The LED will flash.

4. Remove the jumper and leave it disconnected.

The first transmitter synchronised will be the MASTER remote control.

Remotely synchronising the remote control on the receiver with a MASTER remote control

A MASTER remote control is needed for remote synchronisation. The MASTER remote control is the first remote control that is synchronised when the receiver is empty.

1. Press any button on the MASTER remote control for 10 seconds or until the LED flashes 10 times.

2. The LED will light up red.

3. Press the button on the remote control to be recorded.

4. Wait 10 seconds for the receiver to leave synchronisation mode.

GIBIDI® GIOTTO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP YES
  • M-NOVA PRO / BT Slim / M-BT Biometric / M-BT Advance / SR-4V / SR-48
GIBIDI® GIOTTO

CLEMSA® DIGICODE MH Remote

Remove Remote
  • F 433,92
  • C FIX CODE
  • B 1,2,3
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
CLEMSA® DIGICODE MH

The selected remotes can not be copied with a single JMA remote