Frequency
Type of code
- Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
- Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.
Buttons
Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.
PROCESS:
- In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
- Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.
If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.
Copy
No copy
ELEMAT® QUARTZ Remote
BFT® 306 Remote
- F 306
- C FIX CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
ERREKA® CLEM Remote
- F 287
- C FIX CODE
- B 1,2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
JCM® EB Remote
- F 310
- C FIX CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
SIMINOR® CVM Remote
ERREKA® EL Remote
CAME® BIM Remote
DOITRAND® TSDE Remote
- F 433,92
- C FIX CODE
- B 2,4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
ROGER® M80 Remote
CHAMBERLAIN® 9433E Remote
- F 433,92
- C ROLLING CODE
- B 1,3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
NOVOFERM® S41 Remote
ECOSTAR® RSE Remote
- F 433,92
- C ROLLING CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING ECOSTAR ROLLING CODE REMOTE CONTROLS
ECOSTAR remote controls can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button marked P on the PLC or receiver casing. The red LED will begin to flash, indicating that the receiver is in synchronisation mode.
2. Press and hold the button on the remote control until the LED changes to quick flash. Release the button.
3. Press the button on the remote control again and hold until the LED emits very quick flashes. Release the button.
4. The end of the very quick flash phase indicates that the remote control code has been stored.
SIMINOR® CVX Remote
- F 433,92
- C FIX CODE
- B 2,4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
APRIMATIC® TXM Remote
- F 433,92
- C ROLLING CODE
- B 2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING APRIMATIC TXM ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the APRIMATIC TXM remote control
1. Stand near the receiver and press all the emission keys of the device already synchronised in the facility.
The receiver will emit a beep and the LED will flash.
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the original or duplicated remote control.
The LED and buzzer will turn off.
Direct synchronisation procedure for the APRIMATIC TXM remote control
1. Open the receiver and press the small button located near the LED for 2 seconds.
The receiver LED will flash
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the master remote control.
The LED and buzzer will turn off.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
CAME® TOP Remote
CAME® ATO Remote
- F 433,92
- C ROLLING CODE
- B 1,2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING CAME ROLLING CODE REMOTE CONTROLS
CAME ATO remote controls can be synchronised either directly or remotely by taking the following steps.
Synchronisation procedure using the receiver
1. Press the button of the desired channel on the receiver for 2 seconds.
2. The LED on the receiver will flash.
3. Press the button of the same channel on the remote control to be synchronised. Press the button for the same channel on each remote control in turn if you wish to synchronise more than one device.
4. The LED on the receiver will change to steady each time a button is pressed.
5. Repeat the process for the other channel.
Remote synchronising procedure
1. Press the button of the desired channel on the remote control for 15 seconds.
2. The LED on the receiver will flash.
3. Press the button of the same channel on the remote control to be synchronised. Press the button for the same channel on each remote control in turn if you wish to synchronise more than one device.
4. The LED on the receiver will change to steady each time a button is pressed.
SIMINOR® S38 Remote
FORSA® NEO Remote
- F 433,92
- C ROLLING CODE
- B 1,2,3,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING JCM ROLLING CODE REMOTE CONTROLS
The JCM rolling code remote control synchronisation procedure is identical for all models except the 868 MHz.
There are 3 synchronisation procedures for these devices.
PIN-MODE remote synchronising procedure
The following procedure must be applied if the receiver bears the words PIN-MODE:
1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the remote control to be synchronised.
The receiver will emit a long beep, indicating that the device has been successfully synchronised.
Remote synchronisation procedure using the original remote control
1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the synchronised remote control.
The receiver will emit a beep, indicating that it has switched to synchronisation mode.
2. Within 10 seconds of the beep, press the button on the device to be synchronised.
The receiver will emit another short beep to indicate that the remote control has been synchronised.
If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.
3. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.
Direct synchronisation procedure on the receiver
1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".
2. Press the button or turn on the switch.
The receiver will emit a long beep and the LED will light up. From this point, follow the previous procedure from step 2 above.
The selected remotes can not be copied with a single JMA remote