AVIDSEN® 104250 NOIR

AVIDSEN® 104250 NOIR

SYNCHRONISING V2 ROLLING CODE REMOTE CONTROLS

V2 remote controls can be synchronised either remotely or directly on the receiver.

Remote synchronising procedure

1. Press buttons 1 and 2 on the remote control to be synchronised simultaneously for approximately 10 seconds.

2. Release.

3. Within 5 seconds, press any other button on the device to be synchronised.

4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.

The code has been stored.

Since this option is not enabled on all models we recommend the following procedure.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate the small SW1 button.

2. Press until the receiver LED lights up.

3. Within 5 seconds, press the button on the remote control to be synchronised and hold until the receiver LED blinks.

4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.

The code has been stored.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.