Frequency
Type of code
- Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
- Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.
Buttons
Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.
PROCESS:
- In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
- Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.
If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.
Copy
No copy
ALLMATIC® ASMY Remote
- F 306
- C FIX CODE
- B 1,2,4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
DICKERT® MAHS27 Remote
ALLMATIC® AKMY Remote
AVIDSEN® 104250 RED Remote
- F 433,92
- C ROLLING CODE
- B 4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
SYNCHRONISING V2 ROLLING CODE REMOTE CONTROLS
V2 remote controls can be synchronised either remotely or directly on the receiver.
Remote synchronising procedure
1. Press buttons 1 and 2 on the remote control to be synchronised simultaneously for approximately 10 seconds.
2. Release.
3. Within 5 seconds, press any other button on the device to be synchronised.
4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.
The code has been stored.
Since this option is not enabled on all models we recommend the following procedure.
Direct synchronisation procedure on the receiver
1. Open the receiver and locate the small SW1 button.
2. Press until the receiver LED lights up.
3. Within 5 seconds, press the button on the remote control to be synchronised and hold until the receiver LED blinks.
4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.
The code has been stored.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
STAGNOLI® VENUS Remote
- F 433,92
- C ROLLING CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
HOW TO SYNCHRONISE STAGNOLI ROLLING CODE REMOTE CONTROLS
STAGNOLI remote control synchronisation can only be performed directly on the receiver itself.
Synchronising the remote control directly on the receiver:
During start-up, LED1 and LED2 will light up for two seconds as follows:
• LED1 on: Variable code programmed.
• LED2 on: Fixed code programmed.
• Both LEDs on: no transmitter in memory.
Once the receiver is powered up, press the synchronisation button (PG) a number of times corresponding to the operation you wish to complete, holding down the button on the last press.
Synchronisation of the first channel on the receiver: Press the synchronisation button (PG) twice and hold. LED1 will blink twice: press the transmitter button you wish to synchronise.
If the new code has been recognised and synchronised correctly, LED1 will emit a long flash.
By holding the synchronisation button (PG), it is possible to synchronise additional transmitters by pressing the buttons (one at a time) on the additional transmitters to be synchronised.
Synchronisation of the second channel on the receiver: Press the synchronisation button (PG) three times and hold. LED1 will blink three times: press the transmitter button you wish to synchronise.
If the new code has been recognised and synchronised correctly, LED1 will emit a long flash.
By holding the synchronisation button (PG), it is possible to synchronise additional transmitters by pressing the buttons (one at a time) on the additional transmitters to be synchronised.
ALLMATIC® BROWN ROJO Remote
- F 433,92
- C ROLLING CODE
- B 1,2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the BENINCA remote control
1. Stand near the receiver and press the already synchronised hidden transmitter key.
2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.
3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.
The receiver will memorise the new transmitter and exit synchronisation mode immediately.
Direct synchronisation procedure for the BENINCA remote control
1. Open the receiver and briefly press the P button.
The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.
2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.
Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.
3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
The selected remotes can not be copied with a single JMA remote