Legend: Click on the symbols for further information

Frequency

Type of code

  1. Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
  2. Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.

Buttons

Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.

PROCESS:

  1. In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
  2. Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.

If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.

Copy

No copy

APRIMATIC® TX4S Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
APRIMATIC® TX4S

Synchronising intructions

Print

SYNCHRONISING APRIMATIC TXM ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the APRIMATIC TXM remote control

1. Stand near the receiver and press all the emission keys of the device already synchronised in the facility.

The receiver will emit a beep and the LED will flash.

2. Press the synch button of the duplicated device.

The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.

3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the original or duplicated remote control.

The LED and buzzer will turn off.

Direct synchronisation procedure for the APRIMATIC TXM remote control

1. Open the receiver and press the small button located near the LED for 2 seconds.

The receiver LED will flash

2. Press the synch button of the duplicated device.

The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.

3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the master remote control.

The LED and buzzer will turn off.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

APRIMATIC® TX2P Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
APRIMATIC® TX2P

Synchronising intructions

Print

SYNCHRONISING APRIMATIC TXM ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the APRIMATIC TXM remote control

1. Stand near the receiver and press all the emission keys of the device already synchronised in the facility.

The receiver will emit a beep and the LED will flash.

2. Press the synch button of the duplicated device.

The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.

3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the original or duplicated remote control.

The LED and buzzer will turn off.

Direct synchronisation procedure for the APRIMATIC TXM remote control

1. Open the receiver and press the small button located near the LED for 2 seconds.

The receiver LED will flash

2. Press the synch button of the duplicated device.

The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.

3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the master remote control.

The LED and buzzer will turn off.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

AVIDSEN® 104250 NOIR Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 6
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
AVIDSEN® 104250 NOIR

Synchronising intructions

Print

SYNCHRONISING V2 ROLLING CODE REMOTE CONTROLS

V2 remote controls can be synchronised either remotely or directly on the receiver.

Remote synchronising procedure

1. Press buttons 1 and 2 on the remote control to be synchronised simultaneously for approximately 10 seconds.

2. Release.

3. Within 5 seconds, press any other button on the device to be synchronised.

4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.

The code has been stored.

Since this option is not enabled on all models we recommend the following procedure.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate the small SW1 button.

2. Press until the receiver LED lights up.

3. Within 5 seconds, press the button on the remote control to be synchronised and hold until the receiver LED blinks.

4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.

The code has been stored.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

KEY® TXB-44R Remote

Remove Remote
  • F 433,92
  • C FIX CODE
  • B 4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
KEY® TXB-44R

It´s copied with

SR-4V

View Copy Sequence tutorial

SR-4V

M-BT Advance

View Copy Sequence tutorial

M-BT Advance

M-NOVA PRO

View Copy Sequence tutorial

M-NOVA PRO

M-FR1

View Copy Sequence tutorial

M-FR1

BT Slim

View Copy Sequence tutorial

BT Slim

M-BT Biometric

View Copy Sequence tutorial

M-BT Biometric