Frequency
Type of code
- Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
- Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.
Buttons
Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.
PROCESS:
- In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
- Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.
If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.
Copy
No copy
MOTORLINE® MX4SP Remote
- F 433,92
- C ROLLING CODE
- B 4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING MOTORLINE ROLLING CODE REMOTE CONTROLS
MOTORLINE remote controls can only be synchronised directly, using the following procedure.
Synchronisation procedure on the receiver
1. Press the \"SEL\" button repeatedly until the LED marked \"CODE\" lights up steady.
2. Press the button on the remote control to be synchronised
3. After a while the LED will turn off and the remote control will then be synchronised.
CAME® TCH Remote
APRIMATIC® TX-E Remote
- F 433,92
- C ROLLING CODE
- B 2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING APRIMATIC TXM ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the APRIMATIC TXM remote control
1. Stand near the receiver and press all the emission keys of the device already synchronised in the facility.
The receiver will emit a beep and the LED will flash.
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the original or duplicated remote control.
The LED and buzzer will turn off.
Direct synchronisation procedure for the APRIMATIC TXM remote control
1. Open the receiver and press the small button located near the LED for 2 seconds.
The receiver LED will flash
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the master remote control.
The LED and buzzer will turn off.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
APRIMATIC® TX2P Remote
- F 433,92
- C ROLLING CODE
- B 2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING APRIMATIC TXM ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the APRIMATIC TXM remote control
1. Stand near the receiver and press all the emission keys of the device already synchronised in the facility.
The receiver will emit a beep and the LED will flash.
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the original or duplicated remote control.
The LED and buzzer will turn off.
Direct synchronisation procedure for the APRIMATIC TXM remote control
1. Open the receiver and press the small button located near the LED for 2 seconds.
The receiver LED will flash
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the master remote control.
The LED and buzzer will turn off.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
MHOUSE® RT3 Remote
- F 433,92
- C ROLLING CODE
- B 3
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING MHOUSE ROLLING CODE REMOTE CONTROLS
MHOUSE remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.
Remote synchronisation procedure (identical to procedure for NICE, Smilo and Flo-R devices)
1. Press and hold the button on the device you wish to synchronise for at least 5 seconds and then release.
2. Slowly press the button on the previously-synchronised remote control 3 times.
3. Slowly press the button on the device to be synchronised once.
Direct synchronisation procedure on the receiver
1. Press button P1 on the receiver and hold for at least 3 seconds.
2. Release the button when LED P1 lights up.
3. You have 10 seconds to press any button on the device to be synchronised for at least 2 seconds. LED P1 will flash 3 times if synchronisation has been performed successfully.
4. If you wish to synchronise additional remote controls, repeat step 2 within 10 seconds or the receiver will automatically exit synchronisation mode.
ROPER® TRINARY Remote
- F 290
- C FIX CODE
- B 1,2,3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
BENINCA® APPLE Remote
- F 433,92
- C ROLLING CODE
- B 2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the BENINCA remote control
1. Stand near the receiver and press the already synchronised hidden transmitter key.
2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.
3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.
The receiver will memorise the new transmitter and exit synchronisation mode immediately.
Direct synchronisation procedure for the BENINCA remote control
1. Open the receiver and briefly press the P button.
The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.
2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.
Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.
3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
APRIMATIC® TS Remote
- F 306
- C FIX CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
Europe Automatisme® PASS Remote
- F 433,92
- C ROLLING CODE
- B 1,2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the BENINCA remote control
1. Stand near the receiver and press the already synchronised hidden transmitter key.
2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.
3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.
The receiver will memorise the new transmitter and exit synchronisation mode immediately.
Direct synchronisation procedure for the BENINCA remote control
1. Open the receiver and briefly press the P button.
The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.
2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.
Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.
3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
APRIMATIC® TG Remote
MHOUSE® TX4 Remote
- F 433,92
- C ROLLING CODE
- B 4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING MHOUSE ROLLING CODE REMOTE CONTROLS
MHOUSE remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.
Remote synchronisation procedure (identical to procedure for NICE, Smilo and Flo-R devices)
1. Press and hold the button on the device you wish to synchronise for at least 5 seconds and then release.
2. Slowly press the button on the previously-synchronised remote control 3 times.
3. Slowly press the button on the device to be synchronised once.
Direct synchronisation procedure on the receiver
1. Press button P1 on the receiver and hold for at least 3 seconds.
2. Release the button when LED P1 lights up.
3. You have 10 seconds to press any button on the device to be synchronised for at least 2 seconds. LED P1 will flash 3 times if synchronisation has been performed successfully.
4. If you wish to synchronise additional remote controls, repeat step 2 within 10 seconds or the receiver will automatically exit synchronisation mode.
LEB® TQ Remote
ROPER® MINI GO Remote
SYNCHRONISING GO ROLLING CODE REMOTE CONTROLS
The GO remote control is synchronised directly with the receiver the first time the button is pressed. However, this option is disabled on some models, which must be synchronised manually.
GO remote control manual synchronisation procedure
1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".
2. Press the button or turn on the switch.
3. Within ten (10) seconds of the beep, press the button on the device to be synchronised.
The receiver will emit another short beep to indicate that the remote control has been synchronised.
If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.
4. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
ROPER® GO Remote
SYNCHRONISING GO ROLLING CODE REMOTE CONTROLS
The GO remote control is synchronised directly with the receiver the first time the button is pressed. However, this option is disabled on some models, which must be synchronised manually.
GO remote control manual synchronisation procedure
1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".
2. Press the button or turn on the switch.
3. Within ten (10) seconds of the beep, press the button on the device to be synchronised.
The receiver will emit another short beep to indicate that the remote control has been synchronised.
If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.
4. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
BENINCA® IO Remote
CHAMBERLAIN® 9433E Remote
- F 433,92
- C ROLLING CODE
- B 1,3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
DEA SYSTEM® DEA31 Remote
PROTECO® TX 3 Remote
ACM® TX2 COLOR Remote
MOTORLIFT® 9433E Remote
- F 433,92
- C ROLLING CODE
- B 1,3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
LEB® TRK Remote
APRIMATIC® TX4S Remote
- F 433,92
- C ROLLING CODE
- B 4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING APRIMATIC TXM ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the APRIMATIC TXM remote control
1. Stand near the receiver and press all the emission keys of the device already synchronised in the facility.
The receiver will emit a beep and the LED will flash.
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the original or duplicated remote control.
The LED and buzzer will turn off.
Direct synchronisation procedure for the APRIMATIC TXM remote control
1. Open the receiver and press the small button located near the LED for 2 seconds.
The receiver LED will flash
2. Press the synch button of the duplicated device.
The beep will pause and the LED will remain steady for a moment to confirm that it has received the valid code.
3. Wait 30 seconds to exit the synchronisation mode or press the synch or copy button of the master remote control.
The LED and buzzer will turn off.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
LEB® TPW Remote
MOTORLIFT® 94335E Remote
- F 433,92
- C ROLLING CODE
- B 3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
LIFT MASTER® 433EML Remote
- F 433,92
- C FIX CODE
- B 1,3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
LIFT MASTER® 5433E Remote
- F 433,92
- C ROLLING CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
CAME® T152 Remote
ROPER® NEO Remote
- F 433,92
- C ROLLING CODE
- B 1,2,3,4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING JCM ROLLING CODE REMOTE CONTROLS
The JCM rolling code remote control synchronisation procedure is identical for all models except the 868 MHz.
There are 3 synchronisation procedures for these devices.
PIN-MODE remote synchronising procedure
The following procedure must be applied if the receiver bears the words PIN-MODE:
1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the remote control to be synchronised.
The receiver will emit a long beep, indicating that the device has been successfully synchronised.
Remote synchronisation procedure using the original remote control
1. Stand near the receiver and use a pointed object to press the pushbutton at the rear of the synchronised remote control.
The receiver will emit a beep, indicating that it has switched to synchronisation mode.
2. Within 10 seconds of the beep, press the button on the device to be synchronised.
The receiver will emit another short beep to indicate that the remote control has been synchronised.
If the receiver fails to synchronise the device (does not emit the short beep) it may mean that the memory is full and the remote control cannot be synchronised without the installer\'s permission.
3. After 10 seconds the receiver will exit synchronisation mode and emit 2 short beeps.
Direct synchronisation procedure on the receiver
1. Open the receiver and locate a switch or pushbutton labelled \"PROG\".
2. Press the button or turn on the switch.
The receiver will emit a long beep and the LED will light up. From this point, follow the previous procedure from step 2 above.
CHAMBERLAIN® 94335E Remote
- F 433,92
- C ROLLING CODE
- B 3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
CAME® TAM Remote
- F 433,92
- C FIX CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
BENINCA® IO MARRON Remote
- F 433,92
- C ROLLING CODE
- B 2
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the BENINCA remote control
1. Stand near the receiver and press the already synchronised hidden transmitter key.
2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.
3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.
The receiver will memorise the new transmitter and exit synchronisation mode immediately.
Direct synchronisation procedure for the BENINCA remote control
1. Open the receiver and briefly press the P button.
The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.
2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.
Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.
3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
ROLLTORE® R330 Remote
- F 330
- C FIX CODE
- B 1,2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
LIFT MASTER® 84335E/EML Remote
- F 433,92
- C ROLLING CODE
- B 3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
SOMMER® 4025 Remote
- F 868,3
- C ROLLING CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING SOMMER ROLLING CODE REMOTE CONTROLS
SOMMER remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press button B on the receiver
a. Once for channel 1. LED (C1) will light up.
b. Twice for channel 2. LED (C2) will light up.
The receiver will exit synchronisation mode if no code is transmitted during a period of 10 seconds.
To exit synchronisation mode, press key B several times until all LEDs have turned off.
2. Press the desired button (D) on the remote control. The transmitter will send the radio code to the receiver.
The LED for the selected channel will flash and switch off.
Repeat Steps 1 and 2 to synchronise additional transmitters with this receiver.
DEA SYSTEM® GOLDR Remote
- F 433,92
- C ROLLING CODE
- B 1,2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
DAR DE ALTA MANDOS EVOLUTIVOS DEA
SYNCHRONISING DEA ROLLING CODE REMOTE CONTROLS
DEA receivers can work in fixed or rolling code mode. These modes can be selected by placing a jumper in certain positions. The jumper is located in the centre of the circuit board and the positions are marked A (fixed position) and B (rolling code mode).
In rolling code mode, DEA remote controls can be synchronised either remotely or directly on the receiver.
Remote synchronising procedure
1. Stand near the receiver and simultaneously press the two buttons of the device already synchronised in the facility.
The LED on the receiver will light up steady, indicating that it has switched to synchronisation mode.
2. Within 5 seconds, press the button of the device to be synchronised.
The receiver LED will flash and then turn off, indicating that device has been successfully synchronised.
Direct synchronisation procedure on the receiver
1. Open the receiver and press and release the P1 pushbutton located to the right of the circuit board, below a LED.
The LED will light up, indicating that the receiver has entered synchronisation mode.
Be sure to release the P1 button as soon as the LED lights up. If the button is held down until the LED turns off, it will delete the contents of the receiver\'s memory.
2. Press the left button of the device to be synchronised.
The receiver LED will flash once, indicating that device has been successfully synchronised.
3. Synchronisation has been successfully performed. Repeat step 2 for each additional remote control you wish to synchronise. Otherwise, wait until the LED turns off after storing the code and the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices. In this case only the installer will be able to synchronise any new remote controls.
MHOUSE® GTXC Remote
- F 433,92
- C ROLLING CODE
- B 4,8
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING MHOUSE ROLLING CODE REMOTE CONTROLS
MHOUSE remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.
Remote synchronisation procedure (identical to procedure for NICE, Smilo and Flo-R devices)
1. Press and hold the button on the device you wish to synchronise for at least 5 seconds and then release.
2. Slowly press the button on the previously-synchronised remote control 3 times.
3. Slowly press the button on the device to be synchronised once.
Direct synchronisation procedure on the receiver
1. Press button P1 on the receiver and hold for at least 3 seconds.
2. Release the button when LED P1 lights up.
3. You have 10 seconds to press any button on the device to be synchronised for at least 2 seconds. LED P1 will flash 3 times if synchronisation has been performed successfully.
4. If you wish to synchronise additional remote controls, repeat step 2 within 10 seconds or the receiver will automatically exit synchronisation mode.
MOTORLIFT® 75EML Remote
MHOUSE® MOOVO Remote
- F 433,92
- C ROLLING CODE
- B 4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING MHOUSE ROLLING CODE REMOTE CONTROLS
MHOUSE remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.
Remote synchronisation procedure (identical to procedure for NICE, Smilo and Flo-R devices)
1. Press and hold the button on the device you wish to synchronise for at least 5 seconds and then release.
2. Slowly press the button on the previously-synchronised remote control 3 times.
3. Slowly press the button on the device to be synchronised once.
Direct synchronisation procedure on the receiver
1. Press button P1 on the receiver and hold for at least 3 seconds.
2. Release the button when LED P1 lights up.
3. You have 10 seconds to press any button on the device to be synchronised for at least 2 seconds. LED P1 will flash 3 times if synchronisation has been performed successfully.
4. If you wish to synchronise additional remote controls, repeat step 2 within 10 seconds or the receiver will automatically exit synchronisation mode.
BENINCA® IO AZUL Remote
- F 433,92
- C ROLLING CODE
- B 2
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the BENINCA remote control
1. Stand near the receiver and press the already synchronised hidden transmitter key.
2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.
3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.
The receiver will memorise the new transmitter and exit synchronisation mode immediately.
Direct synchronisation procedure for the BENINCA remote control
1. Open the receiver and briefly press the P button.
The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.
2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.
Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.
3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
MOTORLIFT® 4335EML Remote
- F 433,92
- C FIX CODE
- B 3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
MOTORLIFT® 94335EML Remote
- F 433,92
- C ROLLING CODE
- B 3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
DELMA® APOLLO-300-4 Remote
- F 300
- C FIX CODE
- B 4
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
CHAMBERLAIN® 94335EML Remote
- F 433,92
- C ROLLING CODE
- B 3
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS
The Lift Master remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press the button on the remote control and hold.
2. Press and release the Learn button for channel A on the receiver.
3. The control LED will flash once.
4. Release the remote control button.
If you release the remote control button before the control LED flashes the receiver will not accept the code.
Repeat this procedure for any other devices you wish to add.
If you are using a second door, select another button on the remote control and repeat the steps for channel B.
BENINCA® CUPIDO ROJO Remote
- F 433,92
- C ROLLING CODE
- B 2,4
- AP YES
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS
Remote synchronisation procedure for the BENINCA remote control
1. Stand near the receiver and press the already synchronised hidden transmitter key.
2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.
3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.
The receiver will memorise the new transmitter and exit synchronisation mode immediately.
Direct synchronisation procedure for the BENINCA remote control
1. Open the receiver and briefly press the P button.
The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.
2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.
Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.
3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.
Observations
If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.
SOMMER® 4025 433 Remote
- F 433,92
- C ROLLING CODE
- B 2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SYNCHRONISING SOMMER ROLLING CODE REMOTE CONTROLS
SOMMER remote control can only be synchronised directly on the receiver.
Direct synchronisation procedure on the receiver
1. Press button B on the receiver
a. Once for channel 1. LED (C1) will light up.
b. Twice for channel 2. LED (C2) will light up.
The receiver will exit synchronisation mode if no code is transmitted during a period of 10 seconds.
To exit synchronisation mode, press key B several times until all LEDs have turned off.
2. Press the desired button (D) on the remote control. The transmitter will send the radio code to the receiver.
The LED for the selected channel will flash and switch off.
Repeat Steps 1 and 2 to synchronise additional transmitters with this receiver.
GIBIDI® GIBIDI 26,995 Remote
ROLLTORE® R40-330 NEW Remote
- F 330
- C FIX CODE
- B 1,2
- AP NO
- M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
The selected remotes can not be copied with a single JMA remote