Legend: Click on the symbols for further information

Frequency

Type of code

  1. Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
  2. Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.

Buttons

Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.

PROCESS:

  1. In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
  2. Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.

If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.

Copy

No copy

FADINI® ASTRO 75 Remote

Remove Remote
  • F 315
  • C FIX CODE
  • B 1,2,4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
FADINI® ASTRO 75

WAYNE DALTON® 3BTM433 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 3
  • AP NO
WAYNE DALTON® 3BTM433

MHOUSE® MOOVO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
MHOUSE® MOOVO

Synchronising intructions

Print

SYNCHRONISING MHOUSE ROLLING CODE REMOTE CONTROLS

MHOUSE remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.

Remote synchronisation procedure (identical to procedure for NICE, Smilo and Flo-R devices)

1. Press and hold the button on the device you wish to synchronise for at least 5 seconds and then release.

2. Slowly press the button on the previously-synchronised remote control 3 times.

3. Slowly press the button on the device to be synchronised once.

Direct synchronisation procedure on the receiver

1. Press button P1 on the receiver and hold for at least 3 seconds.

2. Release the button when LED P1 lights up.

3. You have 10 seconds to press any button on the device to be synchronised for at least 2 seconds. LED P1 will flash 3 times if synchronisation has been performed successfully.

4. If you wish to synchronise additional remote controls, repeat step 2 within 10 seconds or the receiver will automatically exit synchronisation mode.

ERONE® OVALI Remote

Remove Remote
  • F 433,92
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
ERONE® OVALI

LIFT MASTER® 84335E/EML Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 3
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
LIFT MASTER® 84335E/EML

Synchronising intructions

Print

SYNCHRONISING LIFT MASTER ROLLING CODE REMOTE CONTROLS

The Lift Master remote control can only be synchronised directly on the receiver.

Direct synchronisation procedure on the receiver

1. Press the button on the remote control and hold.

2. Press and release the Learn button for channel A on the receiver.

3. The control LED will flash once.

4. Release the remote control button.

If you release the remote control button before the control LED flashes the receiver will not accept the code.

Repeat this procedure for any other devices you wish to add.

If you are using a second door, select another button on the remote control and repeat the steps for channel B.

HORMANN® HS 868 Remote

Remove Remote
  • F 868,3
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-48
HORMANN® HS 868

AVIDSEN® 104350 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 4
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V
AVIDSEN® 104350

Synchronising intructions

Print

SYNCHRONISING V2 ROLLING CODE REMOTE CONTROLS

V2 remote controls can be synchronised either remotely or directly on the receiver.

Remote synchronising procedure

1. Press buttons 1 and 2 on the remote control to be synchronised simultaneously for approximately 10 seconds.

2. Release.

3. Within 5 seconds, press any other button on the device to be synchronised.

4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.

The code has been stored.

Since this option is not enabled on all models we recommend the following procedure.

Direct synchronisation procedure on the receiver

1. Open the receiver and locate the small SW1 button.

2. Press until the receiver LED lights up.

3. Within 5 seconds, press the button on the remote control to be synchronised and hold until the receiver LED blinks.

4. The receiver LED will turn off after a few seconds, indicating that the unit has exited synchronisation mode.

The code has been stored.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

DICKERT® FHS10B Remote

Remove Remote
  • F 40,685
  • C FIX CODE
  • B 1,2 4
  • AP NO
  • M-Q MAX 2 / M-Q MAX 1
DICKERT® FHS10B

STAGNOLI® VENUS Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
STAGNOLI® VENUS

Synchronising intructions

Print

HOW TO SYNCHRONISE STAGNOLI ROLLING CODE REMOTE CONTROLS

STAGNOLI remote control synchronisation can only be performed directly on the receiver itself.

Synchronising the remote control directly on the receiver:

During start-up, LED1 and LED2 will light up for two seconds as follows:

• LED1 on: Variable code programmed.

• LED2 on: Fixed code programmed.

• Both LEDs on: no transmitter in memory.

Once the receiver is powered up, press the synchronisation button (PG) a number of times corresponding to the operation you wish to complete, holding down the button on the last press.

Synchronisation of the first channel on the receiver: Press the synchronisation button (PG) twice and hold. LED1 will blink twice: press the transmitter button you wish to synchronise.

If the new code has been recognised and synchronised correctly, LED1 will emit a long flash.

By holding the synchronisation button (PG), it is possible to synchronise additional transmitters by pressing the buttons (one at a time) on the additional transmitters to be synchronised.

Synchronisation of the second channel on the receiver: Press the synchronisation button (PG) three times and hold. LED1 will blink three times: press the transmitter button you wish to synchronise.

If the new code has been recognised and synchronised correctly, LED1 will emit a long flash.

By holding the synchronisation button (PG), it is possible to synchronise additional transmitters by pressing the buttons (one at a time) on the additional transmitters to be synchronised.

OPEN OUT® AU1600 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
OPEN OUT® AU1600

Synchronising intructions

Print

SYNCHRONISING GIBIDI ROLLING CODE REMOTE CONTROLS

Direct synchronisation procedure on the receiver

1. Open the receiver and locate the programming button on the circuit board.

2. Press it briefly.

The receiver LED will flash.

3. Within 10 seconds, press the button of the remote control you wish to synchronise.

The receiver will automatically exit synchronisation mode after a short time.

GIBIDI® AU1680 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
GIBIDI® AU1680

Synchronising intructions

Print

SYNCHRONISING GIBIDI ROLLING CODE REMOTE CONTROLS

Direct synchronisation procedure on the receiver

1. Open the receiver and locate the programming button on the circuit board.

2. Press it briefly.

The receiver LED will flash.

3. Within 10 seconds, press the button of the remote control you wish to synchronise.

The receiver will automatically exit synchronisation mode after a short time.

V2® TPQ-AF Remote

Remove Remote
  • F 30,875
  • C FIX CODE
  • B 1,2,4
  • AP NO
  • M-Q MAX 1
V2® TPQ-AF

FORSA® S27M Remote

Remove Remote
  • F 27,09
  • C FIX CODE
  • B 1,2
  • AP NO
  • M-Q MAX 1
FORSA® S27M

KEY® TXP-42 Remote

Remove Remote
  • F 433,92
  • C FIX CODE
  • B 2
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
KEY® TXP-42

SEA® EC 40685 Remote

Remove Remote
  • F 40,685
  • C FIX CODE
  • B 2,4
  • AP NO
  • M-Q MAX 2 / M-Q MAX 1
SEA® EC 40685

CHAMBERLAIN® 433EML Remote

Remove Remote
  • F 433,92
  • C FIX CODE
  • B 1,3
  • AP NO
  • M-BT Biometric / BT Slim / M-FR1 / LITE / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
CHAMBERLAIN® 433EML

The selected remotes can not be copied with a single JMA remote