  1. Fixed. The code emitted by the remote control, is always the same. There is no encryption and once the remote control is duplicated, the copy works directly in the receiver.
  2. Rolling. The code emitted by the remote control, changes with each pulse. A copy of the remote control should be made, that way generating the same brand and model but with a different serial number, that will be necessary for registry in the receiver. There are specific instructions for each receiver of either how to register the copy, remotely or directly manipulating the receiver.

Buttons

Auto-Programmable The remote control can be registered in the receiver without the need of the original remote control, as long as radio communication is activated and the memory is not full.

PROCESS:

  1. In front of the receiver keep the JMA remote control pressed during 10 seconds until the red LED goes off (after 4 seconds) and it turns to green (at 10 seconds).
  2. Once the LED is green, release the button and wait for the LED to definitely go off. During the process, the green LED will flash once or several times depending on the code type until finally going off.

If the process does not work, test the standard method using the original remote control or gaining access directly from the receiver.

Copy

No copy

FADINI® BIRIO Remote

Remove Remote
  • F 868,3
  • C ROLLING CODE
  • B 1,2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
FADINI® BIRIO

Synchronising intructions

Print

SYNCHRONISING FADINI ROLLING CODE REMOTE CONTROLS

FADINI remote controls can be synchronised either directly on the receiver or remotely using a remote control already synchronised with the receiver.

Remote synchronisation procedure

1. Press buttons 1 and 2 simultaneously on the new remote control and hold for 10 seconds.

2. Release, and before 15 seconds elapse press buttons 1 and 2 of the device already synchronised in the facility and hold for at least 10 seconds.

3. Finally, press any button of the device to be synchronised.

Direct synchronisation procedure on the receiver

1. In the receiver, use a jumper to bypass C1.

2. Press button P in the receiver and button 1 on the remote control to be synchronised for 5 seconds.

3. Release the buttons on both devices and remove the jumper.

4. Repeat the operation for all channels, bypassing the relevant channel each time (C2, C3 and C4).

SKY MASTER® TX4 Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance
SKY MASTER® TX4

Synchronising intructions

Print

SYNCHRONISING SKYMASTER ROLLING CODE REMOTE CONTROLS

SKYMASTER remote controls can only be synchronised directly on the receiver. The process is as follows.

Synchronisation procedure on the receiver

1. Press the CODE button once.

The red LED will begin the flash.

2. Press the button on the remote control to be synchronised twice.

The red LED will change to steady and then turn off.

3. Repeat the operation for every button (channel) and every device you wish to synchronise.

If the remote control being synchronised is the first one, you will have to delete the memory as follows:

1. Press and hold the CODE button for 8 seconds during which the LED will remain steady

2. The red LED will turn of and the memory will be deleted.

ALLMATIC® AKMX Remote

Remove Remote
  • F 30,900 / 40,665
  • C FIX CODE
  • B 1,2,4
  • AP NO
  • M-Q MAX 2 / M-Q MAX 1
ALLMATIC® AKMX

ALLMATIC® BRO.OVER Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 3
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
ALLMATIC® BRO.OVER

Synchronising intructions

Print

SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the BENINCA remote control

1. Stand near the receiver and press the already synchronised hidden transmitter key.

2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.

3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.

The receiver will memorise the new transmitter and exit synchronisation mode immediately.

Direct synchronisation procedure for the BENINCA remote control

1. Open the receiver and briefly press the P button.

The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.

2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.

Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.

3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

BENINCA® CUPIDO NEGRO Remote

Remove Remote
  • F 433,92
  • C ROLLING CODE
  • B 2,4
  • AP YES
  • M-BT Biometric / BT Slim / M-FR1 / M-NOVA PRO / M-BT Advance / SR-4V / SR-48
BENINCA® CUPIDO NEGRO

Synchronising intructions

Print

SYNCHRONISING BENINCA ROLLING CODE REMOTE CONTROLS

Remote synchronisation procedure for the BENINCA remote control

1. Stand near the receiver and press the already synchronised hidden transmitter key.

2. Within 5 seconds press the key on the already synchronised remote control that corresponds to the channel to be associated with the new device.

3. Within 5 seconds, press the key of the new device to be associated with the channel selected in step 2.

The receiver will memorise the new transmitter and exit synchronisation mode immediately.

Direct synchronisation procedure for the BENINCA remote control

1. Open the receiver and briefly press the P button.

The red LED on the receiver will light up for 3 seconds, turn off for 1 second and light up for a further 5 seconds.

2. While the red LED is lit up, press the transmitter button that you want to synchronise with channel 1.

Other transmitters can also be entered. You only have to press a key before 5 seconds elapse since the previous device was synchronised.

3. Once finished, wait 5 seconds until the receiver exits synchronisation mode.

Observations

If the procedure fails, it may mean that the receiver memory is full and impedes synchronisation of new devices without the installer\'s permission.

The selected remotes can not be copied with a single JMA remote